  Cold Formed Shapes  
Purlins, girts, eave struts, base members and gable angles shall be cold-formed from steel conforming to ASTM specification A-1011, SS, Grade 55 or ASTM A-1011-HSLAS, Grade 55, Class 1.
  Wall Base Conditions  
Ceco’s standard base condition is to use this member without a panel notch in the concrete foundation since the Base Angle/Trim provides support for wall panels and closes off the open ribs at their base. However, dimensions of member are such that it can be used in conjunction with a panel notch, if so desired by the customer.
  Girts  
Girts are either roll formed “Z” sections, 8 ½” or 10” deep, or roll formed “C” sections, 8 ½” deep. Each flange of these members has a stiffening lip formed at 50° to the flange on “Z”s and at 90° on “C”s.
  Purlins and Eave Struts  
Purlins are roll formed “Z” sections, 8 ½” or 10” deep. Each flange of these “Z”s has a stiffening lip formed at 50° to the flange. Eave struts are roll formed “C” sections, 8 ½” deep nominal (roll formed) with 3 ¼” wide top and bottom flanges; or brake formed “C” sections 10” deep nominal with 3 ¼” wide top flange and 4 ½” wide bottom flange.